Home

  • OXYGEN REFILLING DEVICE
OXYGEN REFILLING DEVICE

OXYGEN REFILLING DEVICE

  • Model No.:HPA-002
  • Capacity:30Nm3/h
  • Purity: 95%
  • Pressure: 15.0MPa
  • Description: Oxygen Refilling Device
  • INQUIRY   EMAIL

Working Principle
The raw air compressed by compressor into the purification system to remove large amount of oil and water, then into PSA oxygen generator system for nitrogen removal, the oxygen then into the oxygen buffer tank and then pressurized by the oxygen booster to rated pressure for preparation of final oxygen package device, package row have two lines, one in work, the other is standby to ensure a continuous package work.

Technical Features
+ Imported pneumatic valves, using life is more than 3 million times;
+ SIEMENS PLC Intelligent program controller, easy and stable operation;
+ Automatic control, stable performance, easy operation.
+ Instant start & stop, able to control the number of filled bottles, saving energy.
Technical Data
+ Oxygen Capacity: 30Nm3/h
+ Oxygen Purity: 95%
+ Oxygen Pressure: 15.0MPa
+ Dew Point: ≤-45℃


MORE SPECIFICATIONS AVAILUABLE

Model Rated Nitrogen Outlput(Nm3/h) Rated Air Processing Amount Membrane Separation Nitrogen(Nm3/h) Rated Hydrogen Processing Amount Membrane Separation Nitrogen(Nm3/h) Installed Power(KW) Cooling Water(T/H)
HPH-10 10 11 0.13 1 0.4
HPH-20 20 22 0.25 3 0.8
HPH-430 40 44 0.45 4 1.2
HPH-60 60 66 0.7 5 1.5
HPH-100 100 110 1.2 8 2.7
HPH-150 150 165 1.7 11 3.5
HPH-200 200 220 2.3 16 4.3
HPH-300 300 330 3.4 24 6.2
HPH-400 400 440 4.5 30 8.6
HPH-500 500 550 5.6 38 10.5




•Fully automatic operation based on most reliable technology.

•Skid mounted design for easy installation.

•Durable zeolite molecular sieves and steel structures ensures longer life.

•Turn-key solution and pre-commissioning.

•Simple operation and lower maintenance cost.

•lower investment and high energy efficiency.

How to get a prompt quotation?

Do not hesitate to send us e-mail with the following data.

1\ N2/O2 flow rate:    _____Nm3/hr
2\ N2/O2 purity:     _____%
3\ N2/O2 discharge pressure:_______Bar
4\ N2/O2  Outlet Dew Point: _____C
5\ Your local Voltages and Frequency:   ______V/PH/HZ
6\ N2/O2  Application_________
7\ You local Sea level_____M

With all above data, we can make a most suitable and correct proposal for you.

What's the order N2/O2 Generator  process?
1\  Inquiry---provide all specific requirements.
2\  Quotation---make a detailed technical proposal.
3\  Negotiation --- process, space, technical communication, layout with CAD drawings, and so on.
4\  Contract confirmation---provide correct contract details.
5\  Payment terms--- T/T 30% in advanced, balanced before shipment.
6\  Produce---mass production
7\  Shipping--- by sea, air or courier. Detailed picture of package will be provided.
8\ Installation and commissioning
9\ After-sales service 24 hours a day.

What is required for standard spare parts?

Please provide model number, serial number, shipping details , and mode of transportation.

How long should we replace the molecular sieve ?

Molecular sieve and our system is regenerative. If the generator is maintained and operated properly, the sieve will last for 8~10 years.

How often should we replace the air filter elements and valves?

To maintain peak performance and protect your investment, it is important to replace the air filter element every six months. The valves should be replaced every five years.

How long does it take to ship a standard spare part ?

An email notification from Express company will be sent to you along with tracking details as soon as it ships.

Where can I download a manual?

Please contact our Service department at service@halpgas.com to request a manual.

Sturdy construction, reliability and low maintenance are further qualities that make our oxygen/nitrogen generators suitable for extreme environments and also become one of the best PSA systems in the market.


Various other advantages are brought into play too when a constant, onsite source of oxygen is available, like mine-related industries. Not only are your lower operating costs, but also energy consumption can be reduced and the additional oxygen removes nitrogen entrainment present in the air.


Hapl’s oxygen generator can be engineered to integrate with any existing system, or designed from scratch. Hapl air can supply constant oxygen of 95% purity through PSA filtration as well as constant nitrogen of 97%~99.999%.


Our Oxygen Generators are capable of producing flow rates from 5 to 500 SM³/hr.

Our Nitrogen Generators are capable of producing flow rates from 10 to 5000 NM³/h.


We can even provide after-sales service 24 hours a day and on-site maintenance to keep everything running perfectly.



MANUFACTURING MEDICAL ENVIRONMENTAL ADDITIONAL
Cutting / Brazing / Soldering Hospital Systems Zone Feed Gas Fish Farming
Glass Work / Blowing
Environmental Remediation
Thermal / Chemical Oxidation

Waste / Water Treatment




COMPANY: Hangzhou Haplgas Equipment Co., Ltd.

CONTACT: Shelly Wang

PHONE: 13758157003

TEL: 0571-23252855

E-mail: info@haplgas.com

ADD: Unit 3 No.702,Dingbei Garden, North Street Art College,Zhuantang Town,Xihu District, HangZhou City, China





Inquiry:

Categories

CONTACT US

Contact: Shelly

Phone: 13758157003

Tel: 13758157003

Whatsapp: +86-13758157003

Email: info@hipale.com

Add: Room 401,Building 1,Wanghe Garden,Tingshan Avenue,Dayuan Town,Fuyang District,Hangzhou City,P.R.China